Online chloride ion analyzer
The principle of Smarter Cl ion selectivity method: An ion selective electrode is an indicator electrode that has selectivity for a specific ion. The Smarter Cl online ion concentration analyzer detects the sample and records the electrode potential. Then, a high-precision diaphragm pump or injection pump is used to add a certain standard solution to the reaction pool and read again. Based on the difference between the two readings, the initial concentration of the sample was calculated, eliminating the influence of other components in the sample. In addition, due to the automatic adjustment of the amount of standard solution added, the measurement range also changes automatically. Within a considerable concentration range, the measurement accuracy can be maintained within 1%.
parameter
performance

Smarter Cl hardware performance analyte: chloride ions

For more parameters, please contact the company's sales department and also refer to the incomplete parameter list

Analog Output

Effective 4-20mA, maximum 500 ohm load

Digital Output

RS232,RS422,RS485,MODBUS

Call the police

Fault alarm, result alarm

Display

7.1 inch LCD color touch screen, 65000 colors

operation temperature

Generally 0 ° -40 ° C

Protection grade

IP 65

Authentication

CE certified

Shell size

730mm x 460mm x 280mm (height x width x depth)

Housing material

High strength glass fiber polycarbonate

Total weight

不带支架约25kg

Operating system*

linux

Software version

Stoya 3.1 (Updatable)

Lumineux 1.0 (capable of iPad wireless operation)

Power supply

230 VAC/115 VAC,50/60Hz

Compatibility

EMC functionality (89/336/EEC), low voltage indication (73/23/EEC), CE

Safety standards

Complies with CENELEC50014/50016 standard

Consumption

110W

 

*There are three different levels of operation: basic level, advanced level, and protection level, all of which can set usernames and

passwords to protect experimental data

Absolute bidirectional data transmission between PC and analyzer;

Automatically retrieve installed hardware;

Confirmation function: Display when power is off;

Dynamic curve function with up to 3 calibration points;

Having the function of historical data curve;

Can be exported to an Excel file;

The instrument's built-in memory can store at least 100000 sets of data;

Can be remotely operated (Lumineux only)

Smarter Cl analysis performance

Analysis methods

Cl ion selective electrode method

Range

10-1000mg/l (range extendable)

Accuracy standard deviation

<1.1%

Reproducibility

<3%

Analysis cycle

Within 1 hour (time can be shortened on its own)

Within 1 hour (time can be shortened on its own)

Unit customers can define themselves, such as%, g/L, mg/L, ppm